 +======Ascent checklists======
 +FIXME
 +=====Pre-Launch=====
 +^  COMM  ^  MET  ^  Panel Section ​ ^  Panel  ^  procedure ​ ^  Panel Area & Notes  ^
 +^  1  |  T-01:​50:​00 ​ |            |  |  | Astronauts Enter The Shuttle ​ |
 +^  2  |  T-01:​40:​00 ​ |  Overhead Left Panel  |  O5  | * set Left Audio XMIT/ICOM mode to VOX/VOX \\ * Set Left Audio A/G (1 & 2) To T/R \\ * Set Left Audio A/A To T/R  \\ * Set Left Audio ICOM (A & B) To T/R  \\ * Set Left Audio (AUD) Power Switch To AUD/​TONE ​ | Activates Commander Communications ​ |
 +^  3  |  T-01:​35:​00 ​ |  Overhead Right Panel  |  O9  | * set Right Audio XMIT/ICOM mode to VOX/​VOX ​ \\ * Set Right Audio A/G (1 & 2) To T/R  \\ * Set Right Audio A/A To T/R  \\ * Set Right Audio ICOM (A & B) To T/R  \\ * Set Right Audio (AUD) Power Switch To AUD/​TONE ​ | Activates Pilot Communications ​ |
 +^  5  |  T-01:​20:​00 ​ |  Front Left Panel  |  F6  | * Check ABORT Light (DIM/​BRIGHT/​DIM) For 8 Seconds | Abort Advisory Check  |
 +^  6  |  T-01:​10:​00 ​ |    |    |  | Flight Control Confirms With Commander that \\ the Side Hatch Is Closed & Locked ​ |
 +^  7  |  T-01:​05:​00 ​ |  Left Panel \\ \\ \\ Front Left panel  |  L2\\ \\ \\ F2  | * Set CABIN VENT ISOL To CLOSE \\ * Set CABIN VENT To CLOSE \\ \\ * Press MASTER ALARM | Cabin Leak Check \\ \\ \\ Cancel Master Alarm Sound  |
 +^  8  |  T-00:​51:​00 ​ |    |    |  | Pilot Confirms IMU Alignment ​ |
 +^  9  |  T-00:​50:​00 ​ |  Right Panel  |  R2  | * Check BOILER PWR (1/2/3) Are ON \\ * Check BOILER CNTLR/HTR (1/2/3) Are On - A \\ * Set BOILER N2 Supply (1/2/3) To ON | Confirm Boiler Power On  |
 +^  10  |  T-00:​45:​00 ​ |  Left Panel  |  L2  | * Set CABIN VENT/VENT To OPEN | Open Cabin Vent  |
 +^  11  |  T-00:​42:​00 ​ |  Center Panel  |  C3 \\ \\ C2  | * Set BFC CRT DISPLAY To ON \\ * Confirm BFC CRT SELECT Is At (3+1) \\ * Enter ITEM 25 EXEC **(Use Left Keypad)** | Enable Backup Flight System (BFS) And \\ Execute Computer Data Transfer To BFS \\ Copy Primary Avionics SW To BFS  |
 +^  12  |  T-00:​36:​40 ​ |  Left Panel  \\ \\  Overhead Low Panel  |  L2 \\ \\ O1  | * Set CABIN VENT To CLOSE \\ * Set CABIN VENT ISOL To OPEN \\ * Check CABIN dP/dT Gauge For Possible Depressurization | Cabin Leak Check - Continued ​ |
 +^  13  |  T-00:​33:​20 ​ |  Left Panel  |  L2  | * Set CABIN VENT ISOL To Close \\ * Check CABIN VENT Is CLOSED | Cabin Pressurization Check Complete ​ |
 +^  14  |  T-00:​30:​00 ​ |  Center Panel  |  C2  | * Enter OPS 101 PRO **(Use Right Keypad)** ​ \\ * Enter SPEC 99 PRO **(Use Right Keypad)** ​ \\ * Press RESUME **(Use Right Keypad)** ​ | Load OPS 1 - Planned 10 Minute Hold \\ Load First Stage SW Into Primary Avionics System ​ |
 +^  15  |  T-00:​29:​00 ​ |  Center Panel  |  C2  | * Enter OPS 101 PRO **(Use Left Keypad)** | Load OPS 1 Into The BFS  |
 +^  16  |  T-00:​26:​00 ​ |  Right Panel  |  R2  | * Set He ISOLATION A (LEFT/​CRT/​RIGHT) To Open \\ * Set He ISOLATION B (LEFT/​CRT/​RIGHT) To Open \\ * Set PNEUMATICS He ISOL To Open \\ * Set 6 ENGINE POWER Switches (LEFT/​CTR/​RIGHT) To ON | Begin The Main Propulsion System (MPS) \\ \\ Helium (He) Pressurization ​ |
 +^  17  |  T-00:​15:​00 ​ |  Front Left Panel \\ Center Panel  |  F6 \\ C3  | * Check ABORT Light ON/OFF For 8 Seconds \\ * Set CAUTION/​WARNING MEMORY To CLEAR | Final Test Of The ABORT System \\ Clear C/W Memory ​ |
 +^  18  |  T-00:​09:​00 ​ |  Right Panel \\ Center Panel  |  R1 \\ C3  | * Set ESS BUS SOURCE (MN B/C, MN C/A, MN A/B) To ON \\ * Set Timer Thumbwheels To 0900 \\ * Set TIMER Switch To SET \\ * Check EVENT TIMER MODE Is DOWN \\ * Set EVENT TIMER CONTROL To START | Enable Fuel Cells,\\ Enable Countdown From Nine (9) Minutes,\\ Start The Countdown ​ |
 +^  19  |  T-00:​08:​00 ​ |  Right Panel  |  R2  | * Check APU FUEL TK VLV (1/2/3) Are CLOSED \\ * Check APU AUTO SHUT DOWN (1/2/3) Are Enable \\ * Check HYD MAIN PUMP PRESS (1/2/3) Are LOW \\ * Check APU SPEED SELECT (1/2/3) Are NORM \\ * Set HYD CIRC PUMP (1/2/3) Set To GPC \\ * Set APU CNTLR PWR (1/2/3) To ON | The Crew Access Arm Is Retracting APU \\ Prestart Check Is Underway |
 +^  20  |  T-00:​05:​10 ​ |  Right Panel \\ \\ \\ Front Center Panel \\ Right Panel \\ Front Center Panel \\ Front Left Panel \\ Right Panel  |  R2 \\ \\ \\ F7 \\ R2 \\ F7\\  F2 \\  R2  | * Set APU FUEL TK VLV (1/2/3) To Open \\ * Check APU/HYD READY TO START (1/2/3) Repeaters-(White) \\ * Set APU OPERATE (1/2/3) To START/RUN \\ * Check HYDRAULIC (APU) Pressure 900psi **(MFD)** \\ * Set HYD MAIN PUMP PRESS (1/2/3) To NORM \\ * Check HYDRAULIC (APU) Pressure 3000psi **(MFD)** \\ * Press MASTER ALARM (If Required) \\ * Set HYD CIRC PUMP (1/2/3) Set To OFF  | APU Start \\ \\ \\ \\ \\ \\ The Master Alarm May Sound Until APU Pressure \\ Reaches 3000 PSI. (Silence Alarm) ​ |
 +^  21  |  T-00:​04:​30 ​ \\ \\  T-00:​04:​10 ​ |  Left Panel  |  L2  | * Set FLASH EVAP FEEDLINE HTR A & B SUPPLY To OFF  | The Shuttle Is On Internal Power. Turn Off Flash \\ Evaporator Feed Line & Heater Supply \\ APU Check  |
 +^  22  |  T-00:​03:​45 ​ \\ \\  T-00:​03:​05 ​ |    |    |  | Start Hydraulic Check, Aero Surfaces Are Moved, \\ A Gimbal Check Is Performed \\ Hydraulic Check Complete ​ |
 +^  23  |  T-00:​02:​55 ​ |    |    |  | External Tank Liquid Oxygen (LOX) Vents \\ Are Closing & The External Tank Begins To Pressurize. \\ External Tank Cap Is Retracted. ​ |
 +^  24  |  T-00:​02:​00 ​ |  Right Panel \\ \\ Center Panel   ​| ​ R2 \\ R1 \\ C3  | * Set APU AUTO SHUT DOWN (1/2/3) To INHIBIT \\ * Set AC BUS SNSR (1/2/3) To MONITOR \\ * Set CAUTION/​WARNING MEMORY To CLEAR | APU Power - Inhibit ​ |
 +^  25  |  T-00:​01:​40 ​ \\  T-00:​01:​20 ​ |    |    |  | Liquid Hydrogen External Tanks Close. \\ Go For Launch ​ |
 +^  26  |  T-00:​00:​00 ​ |    |    |  |  **Shuttle Liftoff** ​ |
  
 +=====Ascent=====
 +^  COMM  ^  MET  ^  Panel Section ​ ^  Panel  ^    procedure ​   ^  Panel Area & Notes  ^
 +^  27  |  T+00:​00:​44 ​ \\  T+00:​01:​10 ​ |            |  |  | Main Engines Throttle Down To 65% \\ Main Engines Throttle Up To 104%  |
 +^  28  |  T+00:​02:​05 ​ |  Front Center Panel  |  F7  | * Check Pressure Pc<50 (MFD / CRT 1) | SRB Separation ​ |
 +^   ​602 ​  ​| ​ T+00:​03:​00 ​ |  Overhead Low Panel  |  O1  |  * Check FREON - EVAP OUT TEMP Gauge Shows Below 60 Degrees ​ | Check Flash Evaporator Is Operational ​ |
 +^  29  |  T+00:​04:​20 ​ |            |  |  | Negative Return ​ |
 +^  30  |  T+00:​06:​56 ​ |            |  |  | Single Engine Press To MECO  |
 +^  31  |  Mission depending \\ \\ Mission depending ​ |            |  |  | Engines Throttle Down In Preparation ​ \\  For Main Engine Cutoff (**MECO**) ​ \\  \\ MECO |
 +^  32  |  Mission depending \\ \\ \\ \\ Mission depending ​ |  Front Center Panel \\ Overhead Right Panel  |  F7  \\  O8  | * Check MAIN ENGINE STATUS Lights (Left/​CTR/​Right) Are Red \\ * Set FWD RCS He PRESS Switches (A & B) To OPEN \\ * Set FWD RCS TANK ISOLATION Switches (1/2 & 3/4/5) To OPEN \\ * Set MANIFOLD ISOLATION Switches (1/2/3/4/5) To OPEN| Confirm Main Engine Shutdown \\ Prepare For External Tank Separation \\ \\ \\ External tank Separation|
 +^  33  |  Mission depending ​ |  Center Panel \\ \\ \\ Overhead AFT Panel \\ \\ Center Panel \\ |  C2  \\ \\ \\  O14  \\  O16  \\ C3 \\ C2  | * Enter ITEM 22 EXEC **(Use Right Keypad)** \\ * Enter ITEM 27 EXEC **(Use Right Keypad)** \\ * Enter ITEM 23 EXEC **(Use Right Keypad)** \\ * Set L OMS ENG VLV To ON \\ * Set R OMS ENG VLV To ON \\ * Set OMS ENG LEFT & RIGHT To ARM/PRESS \\ * Press EXEC - Confirms ready for OMS burn **(Use Right Keypad)** | Prepare For OMS Burn \\ Load Burn Targets, Start Attitude \\ Adjustments,​ Start Countdown Timer \\ \\ \\ \\ Confirm OMS Burn |
 +^  34  |  Mission depending ​ |  Left Panel \\ \\  \\ Center Panel \\ Right Panel \\ \\ \\ Front Left Panel \\ Front Right Panel \\ Center Panel| ​ L1 \\ L2 \\ \\ C3 \\ R1 \\ \\ \\ F6 \\ F8 \\ C3  |* Set FLASH EVAP CONTROLLER PRI A & PRI B To ON \\ * Set FLASH EVAP FEEDLINE HTR A SUPPLY & B SUPPLY To 1 \\ * Set BFC CRT DISPLAY To OFF \\ * Set AC BUS SNSR (1/2/3) To AUTO TRIP \\ * Set O2 TK 1 (B) & O2 TK 2 (B) HEATERS To AUTO \\ * Set H2 TK 1 (B) & H2 TK 2 (B) HEATERS To AUTO \\ * Check FLT CNTLR POWER Is OFF \\ * Check FLT CNTLR POWER Is OFF \\ * Check ORBIRAL DAP - CONTROL Is Set To AUTO| Remaining MPS Propellants Are Dumped Automatically. ​ |
 +^  35  |  Mission depending ​ |  Center Panel  |  C3  | * Enter OPS 105 PRO **(Use Left Keypad)** | Prepare To Circularize Orbit  |
 +^  36  |  Mission depending ​ |  Center Panel \\ \\ \\ Overhead AFT Panel \\ Center Panel  |  C2 \\ \\ \\ O14 \\ O16 \\ C3  | * Enter ITEM 22 EXEC **(Use Right Keypad)** \\ * Enter ITEM 27 EXEC **(Use Right Keypad)** \\ * Enter ITEM 23 EXEC **(Use Right Keypad)** \\ * Confirm L OMS ENG VLV Is ON \\ * Confirm R OMS ENG VLV Is ON \\ * Confirm OMS ENG (LEFT & RIGHT) Are Set To ARM/PRESS| Circularize Orbit  |
 +^  37  |  Mission depending ​ |  Right Panel  |  R2 \\ \\ \\ \\ \\ R4  | * Confirm OMS ENG (LEFT & RIGHT) Are Set To ARM/PRESS \\ * Set 6 ENGINE POWER Switches (LEFT/​CTR/​RIGHT) To OFF \\ * Set He ISOL A (LEFT/​CTR/​RIGHT) To GPC \\ * Set He ISOL B (LEFT/​CTR/​RIGHT) To GPC \\ * Set PNEUMATICS He ISOL To GPC \\ * Set H2 PRESS LINE VENT To OPEN| Propellant Dump Complete ​ |
 +^  38  |  Mission depending ​ |  Right Panel  |  R2 \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ R4  | * Set ET UMBILICAL DOOR - MODE GPC To GPC/MAN \\* Set CENTERLINE LATCH To STOW \\* Set LEFT & RIGHT Door To CLOSE \\ * Check Talkback Shows CLOSE \\ * Set LEFT & RIGHT LATCH To LATCH \\ * Check Talkback Shows CLOSED & LATCHED \\ * Set LEFT & RIGHT DOOR To OFF \\ * Set LEFT & RIGHT LATCH To OFF \\ * Set HYD MAIN PUMP PRESS (1/2/3) To LOW \\* Set APU OPERATE - START/RUN (1/2/3) To OFF \\ * Set APU FUEL TK VLV (1/2/3) To CLOSE \\ * Set APU CNTLR PWR (1/2/3) To OFF \\ * Set BOILER PWR (1/2/3) To OFF \\ * Set BOILER N2 SUPPLY (1/2/3) To OFF \\ * Set HYD CIRC PUMP (1/2/3) To GPC \\ * Set H2 PRESS LINE VENT To GND| Close & Latch The ET Umbilical Doors. APU Shutdown ​ |
 +^  39  |  Mission depending ​ |  Center Panel  |  C2  | * Press EXEC - Confirms ready for OMS burn **(Use Right Keypad)** | Confirm OMS Burn  |
 +^  40  |  Mission depending ​ |  Right Panel \\ Center Panel  |  R4 \\ C2  | * Set PROPELLANT FILL/DRAIN LH 2 OUTBD & INBD To OPEN \\ * Set OMS ENG LEFT & RIGHT To OFF | Liquid He Manual Dump  |
 +^  41  |  Mission depending ​ |  Overhead AFT Panel \\ \\ Right Panel  |  O17 \\ \\ \\ R4  | * Set ATVC (1/2/3/4) To OFF \\ * Set Engine Interface Units - EIU (L-C / C-R / R-L) To OFF \\ * Set MEC (1 & 2) To OFF \\ * Set MPS/TVC ISOL VLV - (SYS 1, SYS 2, SYS 3) To CLOSE| Turn Off Main Engine Controllers ​ |
 +^  42  |  Mission depending ​ |  Right Panel \\ \\ Center Panel \\ Front Left Panel |  R4 \\ \\ C3 \\ F6  | * Set PROPELLANT FILL/DRAIN - LH2 OUTBD To GND \\ * Check PROPELLANT FILL/DRAIN - LH2 INBD To OPEN \\ * ORBITAL DAP/MANUAL MODE - ROTATION YAW, VERN=ON \\ * Set FLIGHT CNTLR POWER To ON \\ * Rotate The Shuttle To Zero Attitude (Pitch/​Roll) **(Joystick - RHC)**| Set Liquid H2 Outboard Fill & Drain Valve To Ground Control \\ Set Attitude Manually \\ Enable Vernier RCS \\ Enable Manual Control Of The RCS \\ Roll=0 - Pitch=0 - Yaw=90 ​ |
ascent-checklist-nooms2.txt ยท Last modified: 2008/09/08 11:48 (external edit)